GEOTECHNICAL ENGINEERING
Sioux Falls, USA
contact@geotechnicalengineering.biz
HomeLaboratoryGrain size analysis (sieve + hydrometer)

Grain Size Analysis for Sioux Falls Soils (Sieve + Hydrometer, ASTM D422)

With a population surpassing 210,000 and an elevation around 1,470 feet on the Big Sioux River, Sioux Falls has seen its construction pace accelerate dramatically over the past decade. Every time a new commercial foundation or roadway subgrade is prepared across Minnehaha County, the gradation of the glacial till and alluvial sediments becomes a decisive factor. We run the full particle size analysis — from coarse sieves down to the hydrometer test for fines — because knowing whether you're dealing with well-graded gravel or a fat clay lens directly shapes compaction specs, permeability estimates, and frost-heave susceptibility. When the project involves deeper bearing layers, we often correlate these results with SPT drilling data to build a complete subsurface profile that satisfies the IBC and local engineering requirements.

A well-graded sand and a uniform silt look identical in a hand auger sample — only the hydrometer curve reveals the difference that matters for subdrain design.

How we work

A common mistake we see in the Sioux Falls area is classifying a soil based solely on visual inspection of the coarse fraction. The quartzite-rich glacial drift deposited here looks deceptively clean, yet the hydrometer test frequently reveals a significant silt content — sometimes exceeding 35 percent — that would completely change the USCS designation from a well-draining sand to a moisture-sensitive silty sand. Our procedure follows ASTM D422 precisely: we start with a representative oven-dried sample, run it through a stack of sieves from No. 4 down to No. 200, and then send the minus-200 material into a sedimentation cylinder with a 152H hydrometer. Temperature corrections, dispersing agent blanks, and meniscus readings are all recorded manually. The resulting grain size distribution curve gives you D10, D30, and D60 values for calculating the uniformity coefficient (Cu) and coefficient of curvature (Cc), which are the numbers that actually tell you how that soil will behave under load and water.
Grain Size Analysis for Sioux Falls Soils (Sieve + Hydrometer, ASTM D422)

Local ground factors

Sioux Falls expanded rapidly after the establishment of the air base in the 1940s, and much of the early industrial development occurred on terraces of the Big Sioux River where fill materials of variable quality were placed over natural floodplain silts. When grain size analysis is skipped or reduced to a quick field sieve, the missing hydrometer data can mask the presence of micaceous silts or thin clay seams that are notorious for causing differential settlement under slab-on-grade floors in this part of the city. The risk is amplified in areas near the river bluffs east of downtown, where thin loess deposits over shale bedrock create a stratified profile that drains poorly. Without a full gradation curve, a contractor might select an open-graded base course that pumps fines into the subdrain system, leading to clogging and frost damage within the first two winters. Our lab has seen this exact failure mode in warehouse parking lots west of I-29, and it always traces back to an incomplete understanding of the fine fraction.

Need a geotechnical assessment?

Reply within 24h.

Email: contact@geotechnicalengineering.biz

Relevant standards

ASTM D422: Standard Test Method for Particle-Size Analysis of Soils, ASTM D2487: Standard Practice for Classification of Soils for Engineering Purposes (Unified Soil Classification System), ASTM D1140: Standard Test Methods for Determining the Amount of Material Finer than 75-µm (No. 200) Sieve, AASHTO T 88: Particle Size Analysis of Soils, IBC Section 1803: Geotechnical Investigations

Other technical services

01

Full Sieve + Hydrometer Package (ASTM D422)

Combined mechanical sieve analysis for particles retained on the No. 200 sieve plus sedimentation hydrometer for the silt and clay fraction, delivered as a semi-log gradation curve with Cu and Cc coefficients.

02

Wash Sieve Analysis (ASTM D1140)

Determination of the minus-200 fraction by wet sieving, suitable for quality control checks on aggregate base course and concrete sand sourced from Sioux Falls quarries.

03

USCS Classification Report (ASTM D2487)

Complete soil classification integrating gradation results with Atterberg limits data, assigning the dual-letter group symbol and full descriptive name required by IBC foundation design chapters.

Typical parameters

ParameterTypical value
Test StandardASTM D422 (Sieve + Hydrometer)
Sieve Range3 in to No. 200 (75 mm to 75 µm)
Hydrometer TypeASTM 152H, scale in g/L
Sample Mass (coarse fraction)500 g to 10 kg depending on max particle size
Dispersing AgentSodium hexametaphosphate (NaPO3)6 solution
Determined CoefficientsCu (uniformity), Cc (curvature), D10/D30/D60
Soil Classification OutputUSCS per ASTM D2487 (GW, SP, CL, ML, etc.)
Reporting FormatSemi-log gradation curve + tabulated % passing

Common questions

How long does a full grain size analysis take in your Sioux Falls lab?

A standard sieve plus hydrometer test per ASTM D422 typically requires three to four business days from sample drop-off to final report. The hydrometer phase alone takes 24 hours because we take readings at precise time intervals — 2, 5, 15, 30, 60, 250, and 1440 minutes — to build the sedimentation curve accurately. If the project is urgent, we can expedite the sieve portion and have the coarse fraction results within 24 hours, with the hydrometer data to follow.

What does a grain size analysis cost for a soil sample from a Sioux Falls construction site?

For a combined sieve and hydrometer analysis on a typical soil sample from the Sioux Falls area, the cost generally ranges between US$100 and US$200. The final price depends on whether we need to run a separate wash sieve for the minus-200 fraction and whether the sample requires extensive drying or disaggregation due to the clay-rich glacial till common in Minnehaha County.

Can I just use a field sieve instead of sending samples to the lab?

A field sieve gives you a rough idea of the coarse fraction, but it will not tell you whether the fines are silt or clay, and it definitely won't give you the D10 needed for filter design or the Cc required for USCS classification. In the silty glacial soils found across much of Sioux Falls, we routinely encounter samples where the hydrometer reveals 20 to 40 percent fines that the field sieve missed entirely, and that difference can change the recommended subgrade treatment from simple compaction to chemical stabilization.

Location and service area

We serve projects in Sioux Falls and surrounding areas.

View larger map